Basic Information |
Part Number |
98011802-001 |
Model |
S5731S-S48S4X-A1 |
Description |
S5731S-S48S4X-A1(48*GE SFP ports, 4*10GE SFP+ ports, AC power, front access) |
Technical Specifications |
Height [mm] |
43.6 mm |
Depth [mm] |
220.0 mm |
Wide [mm] |
442.0 mm |
Chassis height [U] |
1 |
Weight with packaging |
4.85 (10.69) |
Weight without packaging |
3.49 (7.69) |
Maximum power consumption [W] |
121.04 |
Typical power consumption [W] |
87.89 |
Maximum heat dissipation [BTU/h] |
413 |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Typical heat dissipation [BTU/h] |
299.89 |
Power supply mode |
AC built-in |
Input voltage range [V] |
- AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC, 50/60 Hz |
Maximum input current [A] |
3 A |
Number of power slots |
0 |
Number of card slots |
0 |
Memory |
2 GB |
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command. |
Redundant power supply |
Not supported |
Types of fans |
Built-in |
Noise at normal temperature (acoustic pressure) |
27.74 |
Noise at normal temperature (acoustic power) |
41.42 |
Airflow direction |
Air intake from left and front, air exhaustion from right |
Restriction on the operating temperature variation rate |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: |
- The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. |
- The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. |
- The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. |
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. |
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
Long-term operating temperature |
-5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Short-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Storage altitude |
0-5000 m (0-16404 ft.) |
Long-term operating altitude |
0-5000 m (0-16404 ft.) |
MTBF [year] |
31.39 |
MTTR [h] |
2 |
Availability |
>0.99999 |
Maximum number of physical ports on the entire device |
52 |
Maximum number of 100GE ports |
0 |
Maximum number of 40GE ports |
0 |
Maximum number of 25GE ports |
0 |
Maximum number of 10GE ports |
4 |
Maximum number of GE ports |
52 |
Maximum number of FE ports |
48 |
10GE optical interface |
4 |
1000M optical interface |
48 |
USB |
Not supported |
Console port |
RJ45 |
Eth Management port |
RJ45 |
Service port surge protection |
- |
Power supply surge protection |
Differential mode: ±6 kV; common mode: ±6 kV |